Electrical Storage (372-376)
Electrical
energy provided by generators such as PV panels and wind turbines can be stored
on site for later use using Storage components.
Tip: Electric storage devices are included in the model by specifying
them on the Electrical load centre dialog when one of the storage Electrical buss types has been
selected.
There
are 2 ways to model the define the performance of the electrical storage
device:
1-Simple storage - simple definition of the performance of the storage device that
is not intended to represent any specific type of storage technology.
2-Battery - more detailed performance definition of a battery using the
kinetic battery model.
The
type of storage device is defined by selecting the appropriate Category
option
on the Storage dialog.
Simple Storage
The
Simple storage option is accessed by selecting the Simple
storage category
on the Storage dialog. The Simple type of Electrical storage component is used to
model storage of electricity in an Electric load centre. It is a simple model that does not
attempt to represent any of the detailed performance characteristics of a real
storage device such as a battery. The type of power, AC or DC, depends on the
configuration chosen as the Electrical buss type in the Electric
load centre.
Name
This
field contains a unique name for the electric storage device.
Category
There
are 2 categories to choose from:
Simple storage for a simple definition of the performance of batteries or other
storage device.
Battery
for
a more detailed performance definition of a battery
The
Category selected affects the type of model used and the data to be entered on
the Storage dialog.
Availability schedule
This
schedule describes the times when the storage device is available. If storage
is not available, by scheduling a value of 0, then no electrical energy can be
stored or drawn from the device. Any non-zero schedule value means the devices
is available. If this field is blank, the schedule has values of 1 for all time
periods.
HEAT GAIN TO ZONE
Attach to a zone
If
the losses from the storage device should be represented as heat gains to a
zone then check this box and select the zone in the next field.
Zone
This
field contains the name of the thermal zone where the storage device is
located. The selected zone will receive the storage losses as heat gains.
Battery
- 373 -
Radiative fraction
for zone heat gains
This field contains the fraction of storage losses that enter
the zone as long-wave thermal radiation. This should be a factor between 0.0
and 1.0. The balance of the losses are convective. This field is only used when
a zone is attached.
SIMPLE OPTIONS
Nominal energetic efficiency for charging
This field contains the charging efficiency. This is the
energetic efficiency of storing electrical energy in the storage device. A
value of 1.0 means the device does not lose any energy when charging.
Nominal discharging energetic efficiency
This field contains the discharging efficiency. This is the
energetic efficiency of drawing electrical energy from the storage device. A
value of 1.0 means the device does not lose any energy when drawing power.
Maximum storage capacity
This field describes the maximum amount of energy that can be
stored in the device in Joules. Once the storage device is full, no additional
energy can be stored in it.
Maximum power for discharging
This field describes the maximum rate at which electrical
power can be discharged from the storage device (in W).
Maximum power for charging
This field describes the maximum rate at which electrical
power can be stored in the device (in W).
Initial state of charge
This field describes the value for the initial state of
charge in Joules. This is used to model the storage device as having some
amount of stored energy at the beginning of the simulation period.
Battery
Warning: Due to a bug in the EnergyPlus v8 ElectricLoadCenter:Storage:Battery
object the DesignBuilder Battery option causes simulations to fail in models where the solar PV
system is unable to meet the entire building electric load. EnergyPlus
developers have been informed of the problem and we expect it to be fixed in a
future version. In the meantime you are advised to use the Simple
storage option.
The
Battery option is accessed by selecting the Battery category on the Storage
dialog.
Batteries can be used to store charge in an Electric load centre. The battery
bank is a collection of one or more individual battery modules. Given the
surplus or deficit power from the electrical system and the state of charge
from the previous time step, this object can model the voltage, current, and
energy losses with charging and discharging during each time step. The cumulative
battery damage can be also modelled and reported at the end of each simulation
run.
The
battery component allows both Lead-Acid and Nickel Cadmium batteries to be
simulated. With input parameters derived from specific battery tests, the
object is expected to support other battery types such as Lithium-ion
batteries.
The
kinetic battery model assumes that part of the battery’s energy storage
capacity is immediately available in discharging or charging while the rest is
chemically bound. As a function of constant current, the battery capacity is
related to three parameters: the maximum capacity at infinitesimal current, the
capacity ratio of available charges, and the conversion ratio between available
charges and bound charges. These parameters are usually obtained via curve
fitting based on battery data sheets or test data. - 374 -
Each individual
battery module is modelled as a voltage source in series with an electrical
resistance. KiBaM assumes that the internal resistance is constant and the open
circuit voltage varies with the electric current, the state of charge and the
operation mode (charging or discharging). For an individual battery module, the
open circuit voltage at any time is correlated to the voltage at fully
charged/discharged state and three other regression coefficients. These
regression coefficients are usually obtained via curve fitting based on battery
test data.
The object offers user the option to perform battery life
calculation. If battery life is modelled, the user needs to provide a group of
coefficients for the correlation between the number of cycles for battery
failure and the corresponding cycle range. More detailed information can be
found in the Engineering Reference.
Name
This
alpha field contains the identifying name for the battery bank.
Category
There
are 2 categories of electrical storage device to choose from:
Simple storage for a simple definition of the performance of batteries or other
storage device.
Battery for a more detailed performance definition of a battery
The
Category selected affects the type of model used and the data to be entered on
the Storage dialog.
Availability schedule
This
alpha field contains the schedule name (ref. Schedule) that describes when the
battery is available. A schedule value greater than 0 (usually 1 is used)
indicates that electrical energy can be stored or drawn from the battery. A
value less than or equal to 0 (usually 0 is used) denotes that the battery is
not available. If this field is blank, the schedule has values of 1 for all
time periods.
HEAT GAIN TO ZONE
Attach to a zone
If
the losses from the storage device should be represented as heat gains to a
zone then check this box and select the zone in the next field.
Zone
This
field contains the name of the thermal zone where the battery is located.
Entering a valid name of zone here will direct EnergyPlus to include the energy
storage losses as heat gains to the named thermal zone. If the battery is not
within a thermal zone, this field can be left blank and the thermal energy
associated with storage losses is removed from the building model.
Radiative fraction for zone heat gains
This
field contains the fraction of storage losses that enter the zone as long-wave
thermal radiation. This numeric filed should have a value between 0.0 and 1.0.
The balance of the losses is convective. This data is only required when the Attach
to a zone option is checked.
BATTERY STORAGE
Number of battery modules in parallel
This
field defines the number of modules connected in parallel in the battery bank.
Number of battery modules in series
This
field defines the number of modules connected in series in the battery bank.
The total number of modules in a battery bank is equal to the number of modules
in parallel times the number of modules in series. Battery
- 375 -
ذخیرهسازی الکتریکی (372-376)
انرژی الکتریکی ارائه شده توسط ژنراتورها مانند پنلهای PV و توربینهای بادی میتواند با استفاده
از اجزای ذخیرهسازی در محلی برای استفاده بعدی ذخیره شود.
نکته: دستگاههای ذخیرهسازی الکتریکی در این
مدل شامل مشخص کردن آنها در گفتگوی مرکز بار الکتریکی است، زمانی که یکی از انواع باس
الکتریکی ذخیرهسازی انتخاب شده است.
2 روش برای مدلسازی تعریف عملکرد دستگاه ذخیرهسازی
الکتریکی وجود دارد:
1- ذخیرهسازی ساده - تعریف ساده از عملکرد دستگاه
ذخیرهسازی که برای نشان دادن هر نوع خاصی از تکنولوژی ذخیرهسازی در نظر گرفته نشده
است.
2-باتری - تعریف عملکرد دقیقتر باتری با استفاده
از مدل نیروی محرکه باتری.
نوع دستگاه ذخیرهسازی با انتخاب گزینه مناسب دسته در گفتگو ذخیرهسازی
تعریف میشود.
ذخیرهسازی ساده
گزینه ذخیرهسازی ساده با انتخاب بخش ذخیرهسازی ساده در گفتگو ذخیرهسازی
قابل دسترسی است. نوع ساده از اجزای ذخیرهسازی الکتریکی برای مدلسازی ذخیرهسازی
الکتریکی در مرکز بار الکتریکی استفاده میشود. این یک مدل ساده است که سعی در ارائه
هیچ یک از ویژگیهای عملکرد دقیق یک دستگاه ذخیرهسازی واقعی مانند باتری ندارد. نوع
برق، AC یا DC بستگی به پیکربندی انتخاب شده به
عنوان نوع باس الکتریکی در مرکز بار الکتریکی دارد.
نام
این قسمت دارای یک نام منحصر به فرد برای دستگاه ذخیرهسازی الکتریکی
است.
دستهبندی
2 مجموعه برای انتخاب وجود دارد:
• ذخیرهسازی ساده برای تعریف ساده
عملکرد باتری یا دستگاه ذخیرهسازی دیگر.
• باتری برای تعریف عملکرد دقیقتر
باتری
دسته انتخاب شده بر روی نوع مدل استفاده شده و داده در گفتگوی ذخیره
وارد میشوند.
برنامه دسترسی
این برنامه زمانی را که دستگاه ذخیرهسازی در دسترس است توضیح میدهد.
اگر ذخیرهسازی در دسترس نباشد، با برنامهریزی یک مقدار از صفر، پس از آن هیچ انرژی
الکتریکی را نمیتوان ذخیره و یا از دستگاه کشید. هر مقدار برنامه غیر صفر به این معنی
است که دستگاه در دسترس است. اگر این قسمت خالی باشد، برنامه دارای مقادیر 1 برای تمام
دورههای زمانی است.
بهره گرما در منطقه
پیوستن به یک منطقه
اگر تلفات دستگاه ذخیرهسازی باید به عنوان گرما در یک منطقه نشان داده
شود، این جعبه را چک کنید و منطقه را در قسمت بعدی انتخاب کنید.
منطقه
این قسمت شامل نام منطقه حرارتی است که در آن دستگاه ذخیرهسازی قرار
دارد. منطقه انتخاب شده، تلفات ذخیرهسازی را به عنوان افزایش گرما دریافت میکند.
باتری
- 373 -
کسری تابشی برای بهره گرمای منطقه
این قسمت شامل کسری از تلفات ذخیرهسازی است که به عنوان تابش حرارتی
طول موج وارد منطقه میشود. این باید یک عامل بین 0.0 و 1.0 باشد. تعادل تلفات انتقال
حرارت است. این قسمت فقط زمانی استفاده میشود که یک منطقه متصل شود.
گزینههای ساده
راندمان انرژی نامی برای شارژ
این قسمت شامل راندمان شارژ است. این راندمان انرژی ذخیره انرژی الکتریکی
در دستگاه ذخیرهسازی است. مقدار 1.0 بدین معنی است که دستگاه هنگام شارژ هیچ انرژی
تلف نمیکند.
راندمان انرژی نامی برای تخلیه
این قسمت شامل راندمان تخلیه است. این راندمان انرژی از انرژی الکتریکی
کشیده شده از دستگاه ذخیرهسازی است. مقدار 1.0 بدین معنی است که دستگاه هنگام کشیدن
توان، هیچ انرژی تلف نمیکند.
حداکثر ظرفیت ذخیرهسازی
این قسمت حداکثر مقدار انرژی که میتواند در دستگاه بر حسب ژول ذخیره
شود را توصیف میکند. هنگامی که دستگاه ذخیرهسازی کامل است، هیچ انرژی اضافی نمیتواند
در آن ذخیره شود.
حداکثر توان برای تخلیه
این قسمت حداکثر نرخی را نشان میدهد که در آن توان الکتریکی میتواند
از دستگاه ذخیرهسازی (بر حسب وات) تخلیه
شود.
حداکثر توان برای شارژ
این قسمت حداکثر نرخی است که در آن توان الکتریکی در دستگاه (بر حسب
وات) ذخیره میشود.
وضعیت اولیه شارژ
این قسمت مقداری برای حالت اولیه شارژ را بر حسب ژول توصیف میکند. این
برای مدلسازی دستگاه ذخیرهسازی به عنوان داشتن مقدار انرژی ذخیره شده در ابتدای دوره
شبیهسازی استفاده میشود.
باتری